Feasibility
Magnetic and polarized-light heading
Deliver a tactile direction reference using a magnetometer, with polarized skylight as an experimental second channel.
Jump to the test planPublished research
Independent studies · Free-to-read full text
-
Improved Spatial Knowledge Acquisition through Sensory Augmentation
Schmidt et al. · Brain Sciences · 2023 · 10.3390/brainsci13050720
Participants trained with a tactile magnetic compass showed better results on selected spatial tasks. The control group lacked equivalent training and the study did not test industrial interference.
-
Polarized skylight-based heading measurements: a bio-inspired approach
Dupeyroux, Viollet & Serres · Journal of the Royal Society Interface · 2019 · 10.1098/rsif.2018.0878
The robot-mounted experiments support optical heading under specified sky conditions. Acquisition time and 180° ambiguity constrain transfer to a moving wearer.
Technical feasibility
Magnetic heading can be disturbed by steel and nearby equipment. Polarized skylight requires a usable view of the sky and a way to resolve directional ambiguity. Both channels need to indicate unreliable readings.
Proposed first test
Compare each channel with an independent heading reference. Include steel-adjacent routes for the magnetometer and open versus partly blocked sky for the optical channel.
Proposed pass criterion
Target median heading error of 10° or less during declared valid conditions. For the magnetic channel, suppress cues in at least 90% of deliberately corrupted segments. Record how often the optical channel can resolve ambiguity.
These are research targets. This brief reports independent findings and a proposed test plan for SpectraCortex.