Co-development
Contact ultrasonic inspection
Test a tactile threshold cue for an inspector using a contact thickness gauge.
Jump to the test planPublished research
Independent studies · Free-to-read full text
-
Ultrasonic Thickness Measurement Method and System Implementation Based on Sampling Reconstruction and Phase Feature Extraction
Gong et al. · Sensors · 2023 · 10.3390/s23229072
The authors reported errors within ±0.01 mm on calibrated grade 45 steel blocks using their laboratory instrument. Customer parts and the proposed cue need their own evaluation.
-
Vibrotactile Alerting to Prevent Accidents in Highway Construction Work Zones: An Exploratory Study
Yang & Roofigari-Esfahan · Sensors · 2023 · 10.3390/s23125651
Tactile and visual alerts each prompted faster responses than audio in the study’s simulated task. It did not establish a tactile advantage over a visual thickness gauge.
Technical feasibility
Contact ultrasound has a direct measurement precedent. Coupling, geometry and calibration govern measurement quality. The tactile cue should be tested independently against the existing visual workflow.
Proposed first test
Use calibrated test blocks bracketing the inspection threshold. Have trained operators complete a crossover comparison of the usual gauge and the gauge plus a tactile cue.
Proposed pass criterion
Target at least 95% of readings within the customer’s agreed tolerance and at least 20% faster median threshold recognition, with no increase in missed cues.
These are research targets. This brief reports independent findings and a proposed test plan for SpectraCortex.